Factory radiator fan stays on

thomcasey

Well-known member
Joined
Sep 24, 2014
Messages
907
Location
Indianapolis, IN
I just installed a factory primary radiator fan connected to the stock harness. Fan runs when the key is on all the time. Would this be a relay or the thermal resistor?
 

FlyingEagle

Staff member
Joined
Mar 5, 2005
Messages
1,635
Location
THE Ottawa
Checking based upon this diagram, I suggest two easier points to work with.

Galant VR-4 Forums » Galant VR-4 » Technical Discussions » radiator fan wont shut off

Pull the connector on the engine coolant temperature switch. Thermostat housing area.
Pull the connector on the thermo sensor, lower radiator.

Is the fan running low speed or high speed?

Low is controlled by the thermo sensor (for which you could pull the relay - Rad Fan Low)

High is controlled by the engine coolant temperature switch (for which you could pull the relay - Rad Fan High)
 
Last edited:

thomcasey

Well-known member
Joined
Sep 24, 2014
Messages
907
Location
Indianapolis, IN
Thanks! I will check it out. The fan is running at low speed. Also of note, I continue to get an ECTS code after car runs for a minute. Sensor and donned its have been changed, continuity verified and ECU verified (3 different ECUs.
 